Accessory for dew point

Dew point Accessories

Useful accessories for installation and operation of dew point sensors

Accessories Order No. Description Application
A699 3491 Measuring chamber, 1 l/min @ 0.8MPa,fast connector,without filter, max. pressure 1.5MPa, suitable for all SUTO-iTEC dew point sensors For easy connection and disconnection to compressed air system through quick-disconnector.
A699 3493 By-pass-type chamber with 6 mm hose in and out connection up to 1.5MPa This chamber can be used in applications where the measurement gas is by-passed through the chamber.

A699 3500 Patented measuring chamber, 4 l/min @ 0.8 MPa, hose fast connector, with filter, recommended pressure range 0.3 … 1.5 MPa, convinient dew point
measurement of gas/air with S 505.
The sample gas/air is connected to the chamber through a 6 mm teflon hose. The chamber is mounted to the S 505 through the 1/2 ” G-type thread connection. Parking and measurement position is selected through the handle at the chamber, which allows quick measurement results.

A699 3501 Patented by-pass-type chamber with 6 mm hose in and out connection up to 1 MPa, convinient dew point measurement of gas/air with S 505. This chamber can be used in applications where the measurement gas is by-passed through the chamber to avoid any gas/air loss. The chamber is mounted to the S 505 through the 1/2 ” G-type thread connection. Parking and measurement position is selected through the handle at the chamber, which allows quick measurement results.

A699 3496 Measuring chamber for dryer installation, 2 l/min @ 0.8 MPa, hose fast connector, without filter, max. pressure 1.5 MPa The sample gas/air is connected to the chamber through a 6 mm teflon hose. The chamber is mounted to stationary S 2XX dew point sensors through the 1/2 ” G-type thread connection. This chamber can be conviniently mounted to the frame or cabinet of a dryer.
A0699 3690 Chamber for atmospheric pressure dew point This chamber is used where the gas is supplied under pressure (up to 1.0 MPa) but the measurement should be under atmospheric conditions. The measurement result will be atmospheric dew point.
A699 3590 High pressure chamber up to 35 MPa In applications where the pressure is exceeding 1.5 MPa, this chamber can be used. Through the adjustable valve a small purge is set to ensure a gas flow through the sensor element (response time).
A554 0026 Oil/water separator, with quick connect at inlet for 6 mm hose and thread nibble for connection to measuring chamber. Eliminates liquid water and oil from entering the measuring chamber and the sensor unit.
Dew point sensor protection caps Protection caps are used to protect the dew point sensor element from machanal impacts or dust. The proper cap selection depends in application.
Please contact customer service
A554 0002 Test pot 11.3% RH Isuesd to check dew point sensors. The pot creates a constant relativehumidity of 11.3%. The resulting dew point is depending on the ambienttemperature, at 25 ºC it is equal to -6.3 ºC.
A554 0007 Power supply wall mountable, input: 85…264 VAC, output: 24 VDC, 15W, without cable This power supply is used to supply 24 DC to sensors and other devices.
A554 0006 Power supply for hat rail This power supply can be used to supply sensors with 24 VDC/2A. It’s mounted on hat rail.
A553 0104 Sensor cable 5 m, with M12 connector, open wires. Cable can be used to connect SUTO-iTEC sensors to a PLC or power supply.
A553 0105 Sensor cable 10 m, with M12 connector, open wires Cable can be used to connect SUTO-ITEC sensors to a PLC or power supply.
A554 2005 Service kit for sensor configuration including software This service kit can be used for all SUTO-iTEC sensors to change settings and check sensors.
A500 0005 S 51 panel meter, with 4-20 mA input and 2 alarm outputs, 85 … 240 VAC supply, 96 x 48 mm panel Installations in dryers or similar equipment as dew point indicator